TLC500
TLC500

TLC500

Static Bend Radius: 25mm
Dynamic Bend Radius: 50mm
Weight: 0.055Kg/m
Installation & Operating Temperature Range: -55℃~+165℃
Product Detail

Cable Construction Specifications

DescriptionDimensions (mm)Material
1Inner Conductor1.44Stranded SPC
2Dielectric3.85LD-PTFE
3Inner Shield4.05SPC Strip
4Interlayer4.30LD-PTFE
5Outer Shield4.65SPC Braid
6Jacket5.10Blue FEP


Mechanical & Environmental Specifications

Static Bend Radius: 25mm

Dynamic Bend Radius: 50mm

Weight: 0.055Kg/m

Installation & Operating Temperature Range: -55℃~+165℃


Electrical Specifications

Frequency Range: 26.5GTLZ

Cutoff Frequency: 29GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 82%

Shielding Effectiveness: >90dB

Voltage Power: 2000V,DC


Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)


Frequency (MHz)1000200030006000800010000124001800026500
Attenuation (dB/100m)27.138.948.169.681.391.9103.5127.4158.8
Avg.Power (kW)0.8210.5730.4630.3200.2740.2420.2150.1750.140
K1=0.828800
K2=0.000900
Calculation =K1* √FMhz+K2*FMHz


Features & Advantages

Low Loss

Low VSWR

Bending, Shake, Torsion & Pull Resistance


Typical Applications

Aviation Electronics

Electronic Confrontation

Laboratory Test

RF Microwaves Device Test


Inquiry Now
Name: *
Mobile:
E-mail: *
Message: *
Verification code: *
  
Other products
Hot products