TLH1000
TLH1000

TLH1000

Static Bend Radius: 50mm
Dynamic Bend Radius: 100mm
Weight: 0.158Kg/m
Installation & Operating Temperature Range: -55℃~+85℃
Product Detail

Cable Construction Specifications

DescriptionDimensions (mm)Materials
1Inner Conductor2.65Solid SPC
2Dielectric7.00LD-PTFE
3Outer Conductor7.29SPC Braid
4Outer Shield7.58SPC Braid
5Jacket10.00Black PUR


Mechanical & Environmental Specifications

Static Bend Radius: 50mm

Dynamic Bend Radius: 100mm

Weight: 0.158Kg/m

Installation & Operating Temperature Range: -55℃~+85℃


Electrical Specifications

Frequency Range: 15GTLZ

Cutoff Frequency: 16GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 81%

Shielding Effectiveness: >90dB

Voltage Power: 2500V,DC


Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)


Frequency (MHz)1000200030006000800010000124001350015000
Attenuation (dB/100m)22.632.039.255.464.071.679.783.287.7
Avg. Power (kW)0.4540.3210.2620.1850.1600.1430.1290.1230.117
K1=0.714665
K2=0.000012
Calculation=K1* √FMhz+K2*FMHz


Features & Advantages

Low Loss

Flexible


Typical Applications

Wireless Telecommunication Instrument Transmission

Mobile Device Signal Transmission


Inquiry Now
Name: *
Mobile:
E-mail: *
Message: *
Verification code: *
  
Other products
Hot products