TLC220-KJ
TLC220-KJ

TLC220-KJ

Frequency Range: DC-67GTLZ
VSWR: ≤1.4@67GTLZ
Repeated bending: 100,000 times
Temperature Range: -55℃~+125℃
Product Detail

Cable Construction Specifications

DescriptionDimensions (mm)Material
1-6TLC220 Cable2.40FEP
7-8Protect Layer3.60SPC
9-10Jacket4.80PTFE


Mechanical & Environmental Specifications

Frequency Range: DC-67GTLZ

VSWR: ≤1.4@67GTLZ

Repeated bending: 100,000 times

Temperature Range: -55℃~+125℃


Electrical Specifications

Static Bend Radius: 30mm

Dynamic Bend Radius: 50mm

Mechanical Phase: ±7°

Amplitude Stability: ±0.1dB

Weight: 0.052Kg/m


Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)


Frequency (MHz)10002000300060008000100001240018000265004000067000
Attenuation (dB/100m)63.790.8111.9160.4186.5209.8235.2287.1354.0444.0593.2
Avg. Power (kW)0.0970.0680.0550.0390.0330.0290.0260.0220.0170.0140.010
K1=1.975832
K2=0.001221
Calculation=K1* √FMhz+K2*FMHz